No content available.

  • VPOS Error Code - Troubleshooting

Comments

VPOS Error Code - Troubleshooting

VPOS Error Code – Troubleshooting

VPOS Error Code

Error Name

Solution

V01

Relay contacts welded

    1. Turn off power from the charging station.
    2. Contact the supplier for assistance.

      V02

      Relay could not be closed

        1. Contact the supplier for assistance

          V04

          RCD error

            1. Disconnect the cable from the vehicle.
            2. In case the error persists, check input charging cable and input connections.
            3. In case the error persists, contact the supplier for assistance.

              V08

              PE/N wires error

                1. Check the grid input connection.
                2. In case the error persists, contact the supplier for assistance.

                  V10

                  Overvoltage

                    1. Check the grid input connection.
                    2. In case the error persists, contact the charging station provider’s support.

                      V20

                      Overcurrent

                        1. Disconnect the vehicle and consult with the vehicle service.

                          V40

                          Temperature too high 80°+

                            1. Stop charging and wait for the unit to cool down.

                              V80

                              Unsupported charging mode and shorted input phases

                                1. In case of error during charging, check vehicle.
                                2. In case of standby, check grid connection.
                                3. In case the error persists, contact the supplier for assistance.